Lokasi Kami

Jalan Industri Jababeka No.15, Pasirsari, Cikarang Selatan,
Kabupaten Bekasi, Jawa Barat. Kode Pos 17530

CU/XLPE/IS-OS/SWA/PVC

Detail Kabel CU/XLPE/IS-OS/SWA/PVC

CU/XLPE/IS-OS/SWA/PVC adalah kabel yang digunakan untuk menghubungkan instrumen dan sistem kontrol untuk transmisi sinyal analog atau digital. Kabel ini tidak boleh dihubungkan langsung ke suplai listrik utama atau sumber impedansi rendah lainnya dan tidak dirancang untuk digunakan sebagai catu daya. Cocok untuk aplikasi yang ditanam langsung.

Cable Construction :

* Conductor  Plain Annealed Copper wire class 2 according to IEC 60228
* Insulation  Extruded XLPE ( Crosslinked Polyethylene )
* Individual Screen Helically Overlapped Polyester Tape
Tinned Annealed Copper Wire 0.5 mm2 ( 20/0.18 mm )
Helically Overlapped Single coated Aluminium Tape contacted with drain wire
Helically Overlapped Polyester Tape
* Overall ScreenHelically Overlapped Polyester Tape
Tinned Annealed Copper Wire 0.5 mm2 ( 20/0.18 mm )
Helically Overlapped Single coated Aluminium Tape contacted with drain wire
Helically Overlapped Polyester Tape
* Inner Sheath Extruded PVC Flame Retardant ( Black )
* Armour Galvanized Steel Wire
* Outer Sheath Extruded PVC Flame Retardant ( Black or requested by customer )

Pair Identification :

* 1 Pair  Black and White
* Multi PairBlack and White with numbering
Amount of halogen acid gasMax. 17% ( IEC 60754-1)
Limiting oxigen index ( LOI )Min 30% ( IEC 60332-3 annex B )
Sunlight resistanceUL 1581 section 1200
Oil resistanceICEA S-82-552
Flame RetardantIEC 60332-1
Flame PropagationIEC 60332-3 cat. A, B, C
Nominal Voltage300 V dan 500 V
Insul Resistance  Min. 1000 MOhm/km
Test Voltage300 V : 1000 V/1 min
500 V : 2000 V/1 min
Screen ResistanceMin 1 MOhm/km
Min.Bending Radius  6 x OD ( fixed installation )
Temperature Rating-40° C to 70° C
Symbol CU/XLPE/IS-OS/SWA/PVC or P1 T2 IS-OS
Applicable StandardMultipair XLPE Insulated Instrumentation Cable
Flame Retardant, UV Resistant
According to BS EN 50288-7 : 2005
Voltage Designation 300 V & 500 V
P1 T2 IS-OSXLPE Insulated, Individual and Overall Collective Screen, Armoured
Other Specification are available on request
ApplicationSuitable for connecting instrument and control system for analogue or digital signal transmission.These cables shall not be connected directly to mains electricity supply or other low impedance sources and not designed to be used for power supply.Suitable for direct buried applications.

Harga
Hubungi langsung kontak kami di

Whatsapp :

+62 811-3820-9591

+62 811-3820-9592

Telepon :

021-2946-9468

021-8938-4700

Email :

info@rumahlistrikindo.com

Tags :

example, category, and, terms

Share This :

Lokasi kami

Jalan Industri Jababeka No.15, Pasirsari, Cikarang Selatan, Kabupaten Bekasi, Jawa Barat. Kode Pos 17530







Jadwal Operasional

Senin – Jumat: 08.00 s/d 17.00
Sabtu: 08.00 s/d 13.30
Minggu dan Hari Besar: Tutup

Copyright © 2026. All rights reserved.